TEST ITEM | TEST METHOD | UNIT | TEST VALUE |
---|---|---|---|
Hardness | ISO 686 | shoreA | 90±2 |
Specific Gravity | ISO 2781 | g/cm³ | 1.14±0.02 |
Thickness Color | Thickness Gauge Visual Inspection | mm / | 0.05-2.0 Customized |
Tensile Strength | ISO 527-3/5/500 | MPa | CD: 39.1 MD: 36.3 |
Tensile Strength @ 50% Elongation | ISO 527-3/5/500 | MPa | CD: 8.29 MD: 8.19 |
Tensile Strength @ Elongation | ISO 527-3/5/500 | MPa | CD: 11.07 MD:10.93 |
Tensile Strength @ 300% Elongation | ISO 527-3/5/500 | MPa | CD: 15.78 MD: 14.54 |
Elongation at Break | ISO 527-3/5/500 | % | CD: 836 MD: 792 |
Tear Strength | ISO 34-1B | kN/m | CD: 118.4 MD: 110.0 |
Abrasion Resistance | ISO 4649 | mm³ | 36 |
Vicat Softening Point A50 | ISO 306 | ℃ | 97℃ |
Melting Point | Kofler | ℃ | 165-175 |
Brittle Point | DSC | ℃ | -50℃ |